Test Item |
UL Test Procedure |
UL Criteria |
|
Vibration Test |
Cell status:4.2V (full charge) A. Amplitude: 0.8mm B. Frequency:10~55Hz(sweep:1Hz/min) C. Direction: vibrated in three mutually perpendicular directions for 90~100 minutes
|
90% (min) recovery capacity No fire, no leakage
|
|
Thermal Shock Test |
Cell status:4.2V (full charge) A. Stored at 75 C 5 C for 48 hours B. Then moved to -20 C 5 C within 5 minutes and stored for 6 hours
|
No fire, no leakage, no explosion
|
|
Short Circuit Test |
Cell status:4.2V (full charge) A. Copper wire of resistance less than 50mohm B. Short-circuited by connecting copper wire to positive and negtative terminals of battery
|
No fire, no leakage, no explosion |
|
Overchage Test |
Cell status:4.2V (full charge) Charged at 1C/12V for 2.5 hours
|
No fire, no leakage, no explosion
|
|
Thermal Exposure Test |
Cell status: 4.2V (full charge) A. Heated up at a rate of 5 C B. Then moved to -20 C 5 C within 5 minutes and stored for 6 hours
|
No fire, no leakage, no explosion
|
|
High Temperature Test |
Cell status: 4.2V (full charge) Leaving the battery at 90 C for 4 hours
|
No fire, no leakage, no explosion
|
|
Drop Test |
Cell status: half charge Dropped from 1.2m height onto 5cm or thicker concrete with p-tile on it 3 times in each direction at 25 C 2 C.
|
No fire, no leakage, no explosion |